SigmaSchedule
A SigmaSchedule is an ordered sequence of noise levels for a sampling process. A level of 0 represents clean data; 1 represents noise.
For example, [1, 0.75, 0.25, 0] moves from noise toward clean data in three intervals. The intervals need not have equal sizes. Their count does not necessarily equal the number of times a model runs during sampling.
Availability in Studio
Studio recognizes SigmaSchedule as a type, but the current Node catalog has no Node that produces or accepts it. There is no SigmaSchedule input editor to add to a Graph.
Use each generation Node's available sampling settings instead. An Inference Steps setting is a number, not a SigmaSchedule input. Entering a sequence into Text Input creates a String; it does not create a schedule.
Valid sequences
| Requirement | Rule |
|---|---|
| Length | At least two levels. |
| Levels | Finite numbers from 0 to 1, inclusive. |
| Order | Every level must be greater than the previous one, or every level must be smaller. |
| Endpoints | A sequence can cover only part of the range; starting at 1 and ending at 0 is not required. |
Both [0.8, 0.5, 0.2] and [0.2, 0.5, 0.8] are valid. [0.8, 0.5, 0.5] is invalid because it repeats a level. [0.8, 0.3, 0.6] is invalid because it changes direction.
The interval count is one less than the number of levels and must fit within 4,294,967,295. Each level accounts for eight bytes toward the shared value-size limit, which can restrict the length further.
A sampling Node can impose additional requirements on direction, endpoints, or precision. Validity as a SigmaSchedule alone does not establish compatibility with a particular sampling process.